Meaning
Transducer arrangements that use a force transfer pin behind an ejector pin to measure cavity pressure offer a non-invasive alternative to direct melt contact. For indirect pressure measurement, the sensor sits in the ejector plate, registering the force transmitted through the ejector pin. This setup protects the sensor from abrasive polymer melts.
Pin Friction
The accuracy of the reading depends on the fit and friction of the ejector pin within its guide channel. If polymer residue or friction builds up along the pin shaft, the force transferred to the sensor decreases, which results in an artificially low pressure reading. Mould temperature changes also alter the clearance between the pin and the hole, causing variation in the transmitted force.
Engineers must select high precision ejector pins with tight tolerances and maintain clean guide channels to ensure repeatable measurement across long production runs.
Force Calibration
Calculations convert the measured force into an equivalent melt pressure by dividing the force value by the cross sectional area of the ejector pin. Sensor controllers must be programmed with the correct pin diameter to perform this conversion. A mismatch between the pin size and the controller settings causes a scaling error in the output signal.
This correction is performed during the initial setup of the tool to ensure the displayed pressure matches the actual cavity conditions.
Transducer Isolation
Moisture and grease can contaminate the contact surfaces between the ejector pin and the sensor, causing signal drift. Unlike direct sensors, these indirect transducers are less vulnerable to thermal shock because they are isolated from the high temperature melt. This isolation extends the operating life of the sensor and reduces the frequency of replacement.
Mechanical wear on the sensor seat must still be monitored to prevent measurement errors.