Meaning
Piezoelectric output signals sometimes experience a gradual loss or gain in charge that does not correspond to a change in the physical forces within the tool. This unwanted phenomenon, known as cavity pressure drift, typically arises from moisture on the connectors or small electrical leaks in the cables. It distorts the process data and leads to false reject signals during a production run.
Sensor Isolation
Inadequate insulation allows electrical charges to escape from the signal line. High humidity in the moulding shop accelerates cavity pressure drift by creating conductive paths across the cable plugs. Maintaining clean and dry connections prevents these signal errors.
Controller Compensation
Software algorithms can mitigate minor sensor deviations by recalculating the baseline signal between moulding cycles. To counteract cavity pressure drift, the press controller resets the measurement curve to zero before the screw begins its injection stroke. This automatic correction ensures that each shot starts from a clean datum, which prevents the accumulative accumulation of signal errors over long production runs and stabilizes the process.
Hardware Integrity
Physical damage to the coaxial cable or the sensor housing produces permanent signal instability. When insulation resistance falls below the recommended limit, cavity pressure drift becomes too large for the controller to resolve. Recharging or replacing the sensor assembly resolves the issue.