Meaning
Localized thermal energy generation in a flowing polymer melt occurs when the material is forced through a highly restricted orifice at high velocity. This phenomenon, termed micro gate shear heating, is caused by the high shear rates experienced by the polymer chains as they pass through the tiny gate of a micro-moulded part. The resulting temperature spike reduces the melt viscosity, allowing the material to fill the thin-walled sections of the cavity.
Viscosity Modification
Aided flow into intricate cavities is the primary process advantage of this thermal phenomenon. By deliberately designing a micro gate to induce high shear, the processor can lower the injection pressure required to fill difficult part geometries. This viscosity reduction occurs without having to raise the temperature of the entire barrel, which preserves the bulk polymer’s properties.
Degradation Risk
Excessive shear heating will degrade the polymer molecules by scissioning the long-chain structures. This degradation often results in localized discolouration, reduced mechanical strength, or splay marks around the gate area.
Mold Design
Precise dimensioning of the gate is necessary to control the balance between flow assistance and thermal degradation. The tool designer must calculate the shear rate based on the target injection speed and the rheological profile of the specific resin. If the gate diameter is too small, the local temperature can rise well above the polymer’s degradation point during the peak filling phase.