Meaning
Initial compressive force is required to seat a transducer firmly within its mounting pocket. Applying signal pre-load ensures that the sensor detects the very first pressure rise as resin enters the cavity. Without this initial tension, the data may show a delay or a non-linear response during the start of the injection phase.
Seating Pressure
Tightening the mounting nut or spacer applies a physical load to the sensing element. Correct signal pre-load prevents the sensor from moving or vibrating when the high pressure melt strikes the cavity face.
Measurement Range
Sensors have a limited total capacity that includes both the static and dynamic forces. If the signal pre-load is too high, it reduces the available range for measuring the actual melt pressure and may lead to signal clipping or sensor failure.
Calibration Baseline
Zeroing the controller after the sensor is installed accounts for the static force. This step ensures that the signal pre-load does not appear as a false pressure reading on the display. Accurate calibration allows for the tracking of peak pressure and packing time with precision.
The repeatability of the process depends on maintaining a consistent starting point for every sensor in the mould.