Meaning
Leak testing protocols measure the speed at which compressed air or test gas escapes from a sealed internal volume over a specified evaluation interval. Pressure decay rate quantifies pneumatic loss per unit time within a pressurized part cavity, identifying micro-cracks or improper sealing surface alignment. Molded plastic components like fluid reservoirs or medical housings must meet maximum allowable decay thresholds to guarantee hermetic seals in service.
The measurement isolates structural voids caused by sink marks or poor weld line strength. Quantitative decay limits define pass or fail criteria on automated assembly lines.
Testing Protocol
Pressurizing a plastic part expands cavity walls slightly, causing non-leak pressure drops as the material undergoes viscoelastic deformation. Test cycles incorporate a stabilization delay after charging to allow wall expansion and adiabatic temperature changes to settle before measurement begins. Leak detection sensors measure minute pressure changes during the test phase, subtracting baseline creep values from total decay.
Temperature fluctuations in test air alter pressure readings, requiring thermal compensation algorithms. Proper fixture clamping prevents seal deflection from masking actual material leaks.
Defect Correlation
Fast leakage rates indicate structural wall ruptures, severe sink marks, or flash across gasket sealing surfaces. Slow decay rates point to microscopic wall porosity or incomplete weld line fusion created during injection molding. Molders trace persistent decay failures to improper packing pressure or inadequate mold cooling.
Parting line flash on sealing beads disrupts gasket seating, raising pressure loss during leak testing.
Quality Standard
Automated leak testing stations integrate directly into assembly cells, rejecting defective parts immediately after molding. Decay threshold specifications reflect maximum allowable fluid emission limits over component operational lifespans.