Meaning
Standardized testing for barrier films relies on modulated infrared sensor technology to determine moisture transmission through polymeric membranes. The method defined in astm f1249 evaluates the water vapour transmission rate of flexible packaging sheets and boards under controlled steady-state conditions. It establishes uniform procedures that allow resin suppliers and converting plants to verify the barrier integrity of extruded sheets before they enter production lines.
Testing Protocol
Specimen installation requires clamping the plastic specimen as a dry barrier between a wet chamber and a dry chamber. In the astm f1249 procedure, the wet chamber is maintained at a specified relative humidity, while the dry chamber is swept with dry nitrogen carrier gas. This sweep gas carries any permeating water molecules into the sensing system for measurement.
Sensor Technology
Infrared detection systems quantify the absolute mass of moisture by measuring the absorption of light at specific characteristic wavelengths. The sensor used during astm f1249 tests provides a voltage response proportional to the water concentration in the sweep stream. Frequent calibration with reference films of known transmission rates ensures the accuracy of this voltage response.
Moulding Application
Thin-wall injection moulding often employs barrier properties determined by sheet extrusion trials to select resins for food packaging applications. While the standard is written for flat sheets, the transmission values guide the design of parisons and thermoformed shapes where stretching alters the local polymer morphology. Decreased crystallinity during rapid cooling can increase the final transmission rate beyond the values obtained from flat-sheet laboratory measurements.
If the melt temperature is poorly controlled during extrusion, the resulting film might show excessive thickness variations, causing the transmission values to diverge across the roll width and lead to unexpected failures in the field.